skip navigation

CrimeSolutions.gov

Add your conference to our Justice Events calendar

PUBLICATIONS

Register for Latest Research

Stay Informed
Register with NCJRS to receive NCJRS's biweekly e-newsletter JUSTINFO and additional periodic emails from NCJRS and the NCJRS federal sponsors that highlight the latest research published or sponsored by the Office of Justice Programs.

NCJRS Abstract

The document referenced below is part of the NCJRS Library collection. To conduct further searches of the collection, visit the NCJRS Abstracts Database. See the Obtain Documents page for direction on how to access resources online, via mail, through interlibrary loans, or in a local library.

 
  NCJ Number: NCJ 242145     Find in a Library
  Title: Research and Development of Impression Evidence
  Document URL: PDF 
  Author(s): Demos Athanasopoulos, Ph.D. ; Adam Dale ; Eric Sorrentino, M.S.
  Date Published: 05/2013
  Page Count: 40
  Annotation: Project goals were to develop an optimal formula composition of Magneto-Rheological (MR) casting fluid; determine the limitations and benefits of using MR solutions as a casting fluid; and if successful in these efforts, develop a method of creating 3D images for permanent storage of the casting impressions.
  Abstract: The MR solution developed created long-lasting, durable, and high-resolution cases, which facilitated the visualization and analysis of small details not discernible on the object that made the impression. With every MR solution, the casting substrate had to be non-porous, so that the solution was not absorbed by the substrate, as well as non-magnetic so the solution was not affected by the magnetic field of the substrate. In addition to the higher cast resolution, the cast formed instantly once the magnetic field was applied, which is not possible with modern methods. With MR fluids, impression details quickly dissipate after the magnetic field has been removed. In order for MR fluids to be used in a professional setting, a commercially available magnetized container would be necessary. The main benefit of Mikrosil and Dental Stone over the current MR fluids is the permanency of the casts and their ruggedness; however, MR fluids have the capability to collect and preserve evidence with higher accuracy at lower costs, faster set time, and with fewer user errors than Mikrosil or Dental Stone casting. The trial MR fluid compositions were developed through trial and error by adjusting the concentration of the components in the fluid. Of the trial solution prepared for this project, the optimal MR fluid consisted of 25.0 g 325 mesh iron, 0.75 g cellulose, 0.75 g sodium nitrite, 0.15 g sodium chloride, 0.5 g silicon dioxide, and 10.0 mL-distilled water. 1 table, 8 figures, 16 references, and a listing of 2 publications that have disseminated the research findings
  Main Term(s): Criminology
  Index Term(s): Toolmark identification ; Shoe prints and tire tracks ; Casting techniques ; Forensics/Forensic Sciences ; Investigative techniques ; NIJ final report
  Sponsoring Agency: National Institute of Justice (NIJ)
US Department of Justice
Office of Justice Programs
United States of America
  Grant Number: 2009-DN-BX-K204
  Sale Source: NCJRS Photocopy Services
Box 6000
Rockville, MD 20849-6000
United States of America
  Type: Report (Technical)
  Country: United States of America
  Language: English
   
  To cite this abstract, use the following link:
https://www.ncjrs.gov/App/Publications/abstract.aspx?ID=264307

*A link to the full-text document is provided whenever possible. For documents not available online, a link to the publisher's website is provided. Tell us how you use the NCJRS Library and Abstracts Database - send us your feedback.