skip navigation

CrimeSolutions.gov

Add your conference to our Justice Events calendar

PUBLICATIONS

Register for Latest Research

Stay Informed
Register with NCJRS to receive NCJRS's biweekly e-newsletter JUSTINFO and additional periodic emails from NCJRS and the NCJRS federal sponsors that highlight the latest research published or sponsored by the Office of Justice Programs.

NCJRS Abstract

The document referenced below is part of the NCJRS Library collection. To conduct further searches of the collection, visit the NCJRS Abstracts Database. See the Obtain Documents page for direction on how to access resources online, via mail, through interlibrary loans, or in a local library.

 
  NCJ Number: NCJ 245487     Find in a Library
  Title: Performance Evaluation and Utility Assessment of Magneto-Optical Sensor Technology for Detecting and Visualizing Obliterated Serial Numbers in Firearms
  Document URL: PDF 
  Corporate Author: Forensic Technology Center of Excellence (FTCoE)
United States of America
  Date Published: 03/2014
  Page Count: 31
  Annotation: This project evaluated magneto optical (MO) sensor technology for the detection and visualization of obliterated serial numbers in five different metals and one composite material (All materials tested are currently used by firearm manufacturers).
  Abstract: The evaluation found that the MO sensor technology is a valid and reliable method for identifying obliterated serial numbers in ferromagnetic materials. The MO sensor’s operating principle is the Faraday-effect, which allows for the real-time visualization and analysis of the magnetic distribution of sample materials. The technology is manufactured by Matesy GmbH and is commercially available in the United States through Absolute Magnetic Measurements & Solutions, St. Petersburg, FL. This technology requires little to no sample preparation, is easy to use, and allows for the identification of obliterated serial numbers in seconds, with time increasing to minutes at lower detection limits. When compared to the current two gold standards in serial number restoration (chemical etching and magnetic particle inspection), MO sensor technology outperformed both in results and utility with the tested samples. The MO sensor technology’s limitation is its configuration. For this technology to work effectively, the sensor must be in direct contact with the sample, so it can only be used on planar surfaces. Although this restriction limits the detection and restoration of obliterated serial numbers in firearms, it may not limit the detection and deciphering of alterations in documents that use magnetic ink, or the development and visualization of fingerprints using magnetic powder. This report recommends that the application of the MO sensor technology in its current configuration be tested and evaluated in questioned document and latent print examinations. 15 tables, 7 figures, and a 7-item bibliography
  Main Term(s): Criminology
  Index Term(s): Firearms identification ; Forensics/Forensic Sciences ; Investigative techniques ; Manufacturers identification number ; NIJ final report
  Sponsoring Agency: National Institute of Justice (NIJ)
US Department of Justice
Office of Justice Programs
United States of America
  Grant Number: 2011-DN-BX-K564
  Sale Source: NCJRS Photocopy Services
Box 6000
Rockville, MD 20849-6000
United States of America
  Type: Report (Study/Research) ; Test/Measurement ; Report (Grant Sponsored)
  Country: United States of America
  Language: English
   
  To cite this abstract, use the following link:
https://www.ncjrs.gov/App/Publications/abstract.aspx?ID=267572

*A link to the full-text document is provided whenever possible. For documents not available online, a link to the publisher's website is provided. Tell us how you use the NCJRS Library and Abstracts Database - send us your feedback.