Title: EXPERIMENTAL DESIGN AND EVALUATION OF A BOMB TRANSPORT UNIT - PWC (POLICE WEAPONS CENTER) EVALUATION REPORT
Author(s): ANON
Corporate Author: International Assoc of Chiefs of Police
United States of America
Date Published: Unknown
Page Count: 25
Sponsoring Agency: International Assoc of Chiefs of Police
Alexandria, VA 22314
National Institute of Justice/
Rockville, MD 20849
US Dept of Justice

US Dept of Justice NIJ Pub
Washington, DC 20531
Sale Source: National Institute of Justice/
NCJRS paper reproduction
Box 6000, Dept F
Rockville, MD 20849
United States of America
Document: PDF|PDF
Language: English
Country: United States of America
Annotation: THE DESIGN AND CONSTRUCTION AS WELL AS TEST AND EVALUATION OF A BOMB DISPOSAL UNIT ARE DISCUSSED.
Abstract: A DESCRIPTION OF THE DESIGN OF THE CONTAINMENT VESSEL, MATERIAL SELECTION, FABRICATION, AND TRAILER IS PRESENTED. TWO SERIES OF TESTS WERE CONDUCTED ON THE BOMB DISPOSAL UNIT (CONTAINER AND TRAILER) USING 60 PERCENT DYNAMITE AS AN EXPLOSIVE, INCLUDING THE DETONATION OF TWO PIPE BOMBS (2 INCHES IN DIAMETER AND 10 INCHES TOTAL LENGTH) CONTAINING 60 PERCENT DYNAMITE. RESULTS SHOWED THAT THE CONTAINER SAFE LIMIT IS AT LEAST 50 POUNDS OF 60 PERCENT DYNAMITE. IT IS ESTIMATED THAT THE LIMIT OF THE CONTAINER, BEFORE FRACTURE WOULD OCCUR, WOULD BE IN THE RANGE OF 75 TO 100 POUNDS OF 60 PERCENT DYNAMITE. THE TRAILER USED IN THIS BOMB CONTAINMENT UNIT WAS FOUND TO BE INADEQUATE. APPENDIXES PRESENT CERTIFICATION OF MATERIAL AND WELDING PROCEDURES.
Index Term(s): Bomb disposal units; Evaluation; Testing and measurement